
Sunpump Sample Testing Service Center provides one-stop sample testing and technical measurement services based on our in-house platforms including laser ultrasound (LUS), ultrafast transient spectroscopy, LBIC, low-wavenumber Raman, LIBS and micro-imaging spectroscopy. Both courier-sample and on-site testing supported. Contact us for testing proposals and quotations.
With nearly 20 years of experience in laser and optics, Sunpump offers professional sample testing services based on our own platforms: laser ultrasound, LBIC, ultrafast transient absorption/fluorescence spectroscopy, low-wavenumber Raman, LIBS and micro-imaging spectroscopy. Customized testing plans are provided per customer requirement, with complete data and analysis delivered.
Laser Ultrasound: non-contact NDT for internal defects, thickness, stress and coating.
LBIC: light-beam-induced-current imaging for photovoltaic/semiconductor characterization.
Ultrafast Transient Absorption: femtosecond time-resolved spectroscopy for carrier dynamics and excited-state studies.
Ultrafast Transient Fluorescence: time-resolved fluorescence lifetime measurement.
Low-wavenumber Raman: down to 5 cm⁻¹ with ultra-narrowband notch filters.
LIBS: rapid elemental analysis for solids and liquids.
Micro-imaging Spectroscopy: micro-region composition and structure analysis.
1) Requirements discussion; 2) Sample delivery; 3) Testing and data acquisition; 4) Report with spectra and analysis.
Materials characterization & NDT; semiconductor & PV device evaluation; new energy materials; bio/chemical samples; cultural heritage; industrial QC.
Phone: +86 17317958112 · Email: service@sunpump.com.cn. We reply within 1 working day with a free testing proposal.
| Laser Ultrasound | Non-contact NDT: defect/thickness/stress/coating |
| LBIC | Photo-response imaging for PV/semiconductor defects |
| Transient Absorption | Femtosecond pump-probe: carrier/excited-state dynamics |
| Transient Fluorescence | Time-resolved fluorescence: ps–ns lifetime |
| Low-wavenumber Raman | Down to 5 cm⁻¹: lattice vibration/phase transition |
| LIBS | Rapid elemental analysis: solids/liquids |
| Micro-spectroscopy | Micro-region composition analysis |
Laser ultrasound: non-contact, no couplant needed, for harsh surfaces and complex geometries. LBIC: micron-scale spatial resolution defect imaging. TAS: sub-picosecond time resolution pump-probe. Transient fluorescence: ps–ns lifetime. Low-wavenumber Raman: 5 cm⁻¹ cutoff via VBG notch filters. LIBS: spectral elemental analysis. Micro-spectroscopy: micro-region mapping.